Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
SEM Evaluation of the Effects of Laser-Mediated Implant Surface Decontamination: An In Situ Human Pilot Study
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 41 , Issue 5
September/October 2021

Pages 711–717


SEM Evaluation of the Effects of Laser-Mediated Implant Surface Decontamination: An In Situ Human Pilot Study

Eric Linden, DMD, MSD/Charles M. Cobb, DDS, MS, PhD/Paul Fletcher, DDS/Donggao Zhao, PhD


PMID: 34547075
DOI: 10.11607/prd.4911

Successful treatment of peri-implantitis requires decontamination of implant surfaces exposed to biofilms and byproducts of tissue inflammation. In this regard, dental lasers may provide a clinical benefit. While the inherent characteristics of specific laser wavelengths may damage titanium implant surfaces, in vitro and animal studies have shown that damage to the target surface can be avoided with the selection of appropriate laser parameters. In this in situ human study, five hopeless implants were irradiated, each by one of the following lasers: Nd:YAG (1,064 nm), Er,Cr:YSGG (2,780 nm), Er:YAG (2,940 nm), CO2 (9,300 nm), and CO2 (10,600 nm) at their recommended settings. All implants were then removed and examined under scanning electron microscopy for the presence of residual bacteria and to assess the extent of damage to the implant surface. An additional implant (implant no. six) was irradiated and evaluated by the Limulus Amebocyte Lysate test for the presence of residual lipopolysaccharide endotoxin. The results showed that while there were localized areas of heat-related damage to an implant surface following laser irradiation, residual bacteria were rarely noted. Additionally, the Limulus Amebocyte Lysate test indicated a nearly complete removal of endotoxin. With the use of appropriate settings, all current dental lasers can be utilized for implant surface decontamination in a human.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help